Gongyi Yulin Welding Material Co., Ltd
|
Price: | 600.0 USD |
Payment Terms: | T/T,L/C |
Place of Origin: | Henan, China (Mainland) |
![]() |
|
Add to My Favorites | |
HiSupplier Escrow |
Name: Agglomerated submerged arc welding flux SJ501
AWS: AWS/ASME SFA-5.17 F6A2-EL8 F6A2-EM12 F7A0-EL12 F7A2-EM12K
SAW wires: EL8, EM12K, etc.
Power supply: DC (DCEP), AC
Basicity: 0.5-0.8 BIIW.
Grain size: 10-60 mesh (0.28-2.0mm).
Alloy transfer: Si, Mn alloying
Category: submerged arc welding mild steel & low-alloy steel
Industry: LPG cylinder, gas bottle, pressure vessel, power plant, boiler water wall, etc.
Description: acid type agglomerated alumina &
rutile based flux. Stable arc. Uniform weld metal surface. Smooth
welding bead
appearance. SJ501 is for the use of multiwire high speed welding up to 70m/h. Especially suitable for boiler
water-wall tubes welding, twin
wire single pass welding, fillet welding, butt
welding and thin sheet welding. High tolerance to impurities like rust,
oil, water, paint, etc.
Package: damp-proof packing, 25kg/bag
Certification: ABS, CCS, LR
SiO₂+TiO₂ | Al₂O₃+MnO | CaF₂ | S | P |
25-35 | 50-60 | 3-10 | ≤0.03 | ≤0.08 |
Accompanied Wire |
Yield Strength ReH (δs) MPa |
Tensile Strength Rm (σb) MPa |
Elongation A (δ5)% |
Charpy-V lmpact Test (J) | ||
+20℃ | 0℃ | |||||
EL12 | ≥360 | 420-550 | ≥22 | ≥50 | ≥27 | |
EM12K | ≥420 | 500-650 | ≥22 | ≥50 | ≥27 |
1.
We get values in data sheets from tests carried out in accordance to
AWS and GB standard procedure. They only represent values we get under
those conditions. They are not to be taken as guarantees. As to welding,
individual test results may vary depending on experience &
technique, flux type, base metal, joint preparation,
flux preparation, ampere, voltage, etc.
2. If welding fluxes are stored in improper environment or influenced by
condensed moisture, anyway, they get damp, please dry them at 300-350℃ for 2 hours before usage.
3. Please clean the rust, oil, water on base metal before welding.
4. Add minumum 20% new flux when using
recovered flux to avoid welding defects and maintain welding performance
& mechanical properties.
5. Please control parameters properly, like preheat temperature, interpass temperature, cooling rate.